Gate Resistor Power and Stress Evaluator

Estimate gate resistor average power, pulse energy, peak stress, package margin, and parallel resistor sharing for power switch gate-drive design.

Gate-drive resistor screening

Average Power Status

Fail · Pulse Check Required

Fail

At least one physical resistor exceeds 20% of its typical package rating. Increase package size or parallel count, or reduce drive energy.

Gate-Drive Load

No Qgd, Miller plateau, switching-time, dv/dt, di/dt, switching-loss, overshoot, or ringing estimate is made.

ΔVg21.0 V
Total gate-drive power172.20 mW
Average supply current8.20 mA
Energy per switching cycle1.722 µJ
Equivalent gate charge82.00 nC
Initial charge current2.727 A
Initial discharge current3.818 A

External Resistor Banks

Average loss is checked against 20% of the selected package typical rating. Passing average power does not prove repetitive-pulse capability.

Selected configuration

Turn-on resistor bank

10.0 Ω × 2 · 0805

Fail
Effective resistance5.0 Ω
Total bank loss55.91 mW
Loss per resistor27.95 mW
Energy per resistor per pulse279.5 nJ
Initial instantaneous power per resistor18.60 W
Typical package rating125.00 mW
20% design limit25.00 mW
Rated-power loading22.4%
20% design-limit utilization111.8%

Selected configuration

Turn-off resistor bank

3.3 Ω × 1 · 0805

Fail
Effective resistance3.3 Ω
Total bank loss51.66 mW
Loss per resistor51.66 mW
Energy per resistor per pulse516.6 nJ
Initial instantaneous power per resistor48.11 W
Typical package rating125.00 mW
20% design limit25.00 mW
Rated-power loading41.3%
20% design-limit utilization206.6%

Loss Distribution

External resistor loss107.57 mW
Driver output-stage loss24.38 mW
Internal gate-resistance loss40.25 mW

Engineering Boundary

Average-power acceptance does not prove pulse capability; verify the exact resistor series data sheet, ambient-temperature derating, PCB conditions, and repetitive-pulse curve.